Gamma Radiation Exposure

Two PotCon ™ Sealed Connectors were exposed to gamma radiation at a rate of 1.5 x 10 R/Hour and helium leak tested after doses of 100 m rad. Leak rates after this test were less than 4.3 x 10 cc/sec and all pin-pin resistance was greater than 10 ohms. Tests were performed on compound 1469/1481 (AECL 29-63174-300-000).

Feedthrough Flammability Tests

Potting flammability test on three harness feedthroughs with two #12 AWG wires. Ultimate current applied 175a in air and 145a in 100% oxygen. No flame was noted throughout and the feedthrough test was concluded after conductor fusion. Feedthrough tests were performed on compound 1469/1481 (WSTF #79-11713).

Upward flammability tests also in air and 100% oxygen exposure resulted in a self-extinguished report. Feedthroughs tests were performed on compound 1469/1481 (WSTF #79-1173).

A UL ® flammability test was performed on compounds 1469/1470, 1469/1481, 7113/1470 and 7113/1481. All achieved a 94HB classification. (E92366, 84ME10295)

Water Vapor Transmission

Three samples of 1469/1481 epoxy at 0.125" thickness was tested per ASTM-E-96-80. The average for the feedthroughs tests was 7e-5 gms/day/cm.

Feedthrough Outgassing Tests

Samples of the materials were heated in a 10 Torr vacuum to 125° C. The chamber was pumped through, and the flow during the test was passed over and optical glass condensing surface at 25° C the results are detailed:

Compound

%Wt Loss

% VCM

Visible Deposits

1469/1470

0.33%

<0.002%

None

1469/1481

0.22%

<0.002%

None



Feedthrough Explosion Proof Testing

The following tests were performed by ULŪ labs on lead wires sealed in a fitting using compound 26987, with the results indicated:

Leakage of Sealing Fitting test: Passed < 0.007ft
Hydrostatic Pressure Test: Passed 6.000 psi
Accelerated Air Oven Aging: Passed 168h @ +70° C.
Solvent Vapor Resistance Test: Passed 13 chemical vapor exposure tests.

We will participate willingly in the testing of samples of other designs.

Leachable Cations and Anions

A sample of our 1469/1481 epoxy 150 C and 100% RH was analyzed for leachable cations and anions:


Cations (ug/g) Anions (ug/g
AI 0.40 F <0.1
Ca 0.27 CI 2.4
Li 0.03 NO3 <0.2
Mg 0.024 SO4 <0.2
Na 6.3 Br <0.2
K 0.016 NO2 <0.1
Cu 0.026 HPO4 <0.2
Zn 0.045    